Codes d'erreur Grow Manager
Votre box affiche un code de la forme GM-000 ? Saisissez-le, ou cherchez-le dans la liste.
Démarrage
7| GM-101 | Normal boot | Information |
| GM-102 | Automatic safety restart (hardware watchdog) | Avertissement |
| GM-103 | Restart after 10 consecutive errors | Erreur |
| GM-104 | Stuck button detected at boot | Avertissement |
| GM-105 | Anti-flood safety applied at boot | Critique — mise en sécurité |
| GM-106 | Factory reset triggered by button | Avertissement |
| GM-107 | Boot error retained | Erreur |
Réseau
9| GM-201 | WiFi unreachable, switching to Ethernet | Avertissement |
| GM-202 | Ethernet absent, switching to WiFi | Avertissement |
| GM-203 | No network available | Erreur |
| GM-204 | Server unreachable | Erreur |
| GM-205 | Authentication key refused - going offline | Critique — mise en sécurité |
| GM-206 | Synchronisation timeout | Avertissement |
| GM-207 | Network interfaces reset | Avertissement |
| GM-208 | Server connection restored | Information |
| GM-209 | WiFi connection failed despite a stored configuration | Erreur |
Horloge
4| GM-301 | Invalid clock - equipment set to safe state | Critique — mise en sécurité |
| GM-302 | Hardware clock unavailable - internal clock fallback | Avertissement |
| GM-303 | Clock resynchronised | Information |
| GM-304 | Daylight saving change applied | Avertissement |
Capteurs
9| GM-401 | Air sensor (temperature/humidity) missing | Erreur |
| GM-402 | Air sensor read error | Erreur |
| GM-403 | Air sensor back online | Information |
| GM-404 | Soil probe: read failed | Erreur |
| GM-405 | Soil probe stuck or out of calibration | Avertissement |
| GM-406 | Internal bus locked - recovery attempted | Critique — mise en sécurité |
| GM-407 | Probe failure - equipment forced OFF | Critique — mise en sécurité |
| GM-408 | Probe back online | Information |
| GM-409 | Soil probe declared unused - rule ignored | Information |
Prises et variateur
8| GM-501 | Socket configuration missing - no command can be sent | Critique — mise en sécurité |
| GM-502 | Socket without radio code - command ignored | Erreur |
| GM-503 | Radio transmission failure | Erreur |
| GM-504 | HPS lamp safety active - ignition delayed | Information |
| GM-505 | Dimmer: requested level out of range | Avertissement |
| GM-506 | Socket test: deliberate power-on | Information |
| GM-507 | Socket test not possible | Avertissement |
| GM-508 | Lamp state asserted at boot | Information |
Programmes
12| GM-601 | Preset not found - default loaded | Erreur |
| GM-602 | Preset unreadable | Erreur |
| GM-603 | Preset replaced by server version | Avertissement |
| GM-604 | Rule ignored - the target socket is not declared | Avertissement |
| GM-605 | Unknown or inconsistent rule type - ignored | Erreur |
| GM-606 | Two rules conflict on the same socket | Avertissement |
| GM-607 | Preset execution error | Erreur |
| GM-608 | Self-test executed | Information |
| GM-609 | Decision explanation | Information |
| GM-610 | Preset rejected - previous one stays active | Erreur |
| GM-611 | Preset diverged between box and server | Avertissement |
| GM-612 | Socket configuration diverged between box and server | Avertissement |
Arrosage
11| GM-701 | Watering started | Information |
| GM-702 | Watering finished | Information |
| GM-703 | Watering blocked: daily quota reached | Avertissement |
| GM-704 | Watering blocked: wrong pump for this day | Avertissement |
| GM-705 | Watering blocked: night in less than 2 hours | Avertissement |
| GM-706 | Safety: pump cut after duration overrun | Critique — mise en sécurité |
| GM-707 | Pump not found | Erreur |
| GM-708 | Watering loop error | Critique — mise en sécurité |
| GM-709 | Persistently dry soil - tank probably empty | Avertissement |
| GM-710 | Watering loop back online | Information |
| GM-711 | Nutrient days ignored: no nutrient pump configured | Avertissement |
Configuration et appairage
7| GM-801 | Configuration unreadable - back to setup mode | Erreur |
| GM-802 | Configuration write failure | Erreur |
| GM-803 | Pairing code expired or invalid | Avertissement |
| GM-804 | WiFi password refused | Erreur |
| GM-805 | Diverging configurations - reconciled | Avertissement |
| GM-806 | Box paired to an account | Information |
| GM-807 | Box unlinked - back to setup mode | Information |
Mise à jour
4| GM-901 | Update available | Information |
| GM-902 | Update download failed | Erreur |
| GM-903 | Corrupted update - installation cancelled | Erreur |
| GM-904 | Update installed | Information |
Un code n'est jamais réattribué : sa signification ne change pas d'une version à l'autre.